An oxygen concentrator pulls ordinary room air through a series of filters and separators and delivers the enriched portion through a nasal cannula or mask. Everything else is exhausted back into the room. That is the whole principle, and it is why a concentrator never runs out the way a cylinder does.

The meaningful difference between units on the market is not the principle but the delivery mode and the resulting purity. Getting that distinction right at the specification stage is the difference between a patient who uses their equipment through the night and one who quietly stops.

Continuous flow: what it delivers

A continuous-flow concentrator draws a fixed flow of air through the separator and outputs a steady stream at a set litre-per-minute rate, typically 1–5 L/min. Because the device is producing a continuous flow rather than delivering a measured dose on demand, purity stays close to 90–96% across the whole flow range. It dips slightly at higher settings but remains predictable.

This is the type prescribed when a patient needs a known, steady quantity of oxygen — overnight use, or a flow high enough that a triggered dose would be impractically large. It is also the type required for most institutional applications, because a fixed, metered flow can be written into a protocol and checked.

Pulse dose: how it differs

A pulse-dose concentrator only produces oxygen when the wearer inhales. It detects the effort of each breath and delivers a short, measured bolus of essentially pure oxygen. Because the machine runs far less of the time, the batteries last much longer and the unit is far smaller — typically a shoulder bag rather than a floor unit.

The trade-off is purity. Since the device is idle between breaths, it cannot maintain a continuous concentration — typical output is 88–92% measured at the cannula, and effective delivery depends heavily on how well the unit is fitted and how slowly the patient breathes. A patient who breathes rapidly and shallowly will receive less oxygen than the same prescription suggests.

Pulse dose suits someone who is mobile and needs oxygen intermittently. It does not suit a patient who is sleeping, since breathing slows and shallowly during sleep and a triggered device delivers correspondingly less. This is one of the more consequential mismatches in home oxygen provision, and it is worth checking explicitly at the point of prescription.

How the separation works

Air enters through a filter that removes dust and allergens. It is then either molecular sieve or membrane technology, depending on the design:

  • Molecular sieve units use zeolite beads that adsorb nitrogen at higher partial pressure and release it when the pressure falls, alternating between two or more towers so output is continuous.
  • Membrane units pass oxygen through a selective polymer while nitrogen and other components are vented. They run continuously, respond faster to flow changes, and are quieter in operation.

Either way the output is air enriched to around 90% oxygen rather than pure oxygen, and the remainder is returned to the room. This is why a concentrator is described as an oxygen-enrichment device, and why its exhaust does not need to be vented — the reason it can sit in a bedroom at all.

One consequence of that exhaust being harmless is worth stating plainly: because the unit enriches the surrounding air slightly, it should not be run in a very small, poorly ventilated space for long periods. It is designed for normal domestic and clinical rooms, not for cupboards.

What determines whether a patient is a good fit

  • Required flow rate in litres per minute, measured while sleeping as well as awake.
  • How long the concentrator must run each day — this determines battery or mains power strategy.
  • Whether the patient is mobile during use, and whether travel or flights are involved.
  • Noise tolerance, since continuous units sit in bedrooms and run all night.
  • Whether humidification is required, and whether the patient tolerates a nasal cannula for long periods.

A common source of poor outcomes is a unit that meets the daytime flow but cannot sustain it during sleep, when breathing slows and the required flow often rises. Any prescription should specify the overnight requirement explicitly, and the equipment should be verified while the patient is actually asleep — not in the clinic chair.

Practical notes for homes and clinics

Place the unit where airflow is not restricted — not in a cupboard, not against a wall that blocks the intake, not on soft furnishing. Leave the exhaust path clear. Tubing length adds resistance, so keep it to what the patient actually needs rather than to the length of the room.

Humidification bottles reduce nasal dryness but can become a contamination source. They need cleaning on a schedule, and many patients do better with a heated humidifier or simply with a nasal spray. A humidifier that is not cleaned is a worse outcome than no humidifier.

Power supply is another quiet constraint. A continuous unit that is also a battery unit will, in practice, end up on mains overnight and lose its portability the moment the patient relies on it. Deciding which mode a given device is primarily for before purchase avoids buying a compromise that does neither job well.

Maintenance that is actually needed

  • Replace the intake filter on schedule — dirty filters cut output without any visible fault, and this is the most common cause of a patient reporting that their machine "does not work any more".
  • Clean or replace the humidifier bottle regularly, following the manufacturer's stated method.
  • Check tubing for kinks or hardening, and replace rather than clean when hardened.
  • Keep the device away from dust, oil vapour and cleaning products — many are drawn in by the intake.
  • Have the output verified with an oxygen analyser after any service or filter change.

Filter replacement is the one task that gets skipped and the one that matters most. A concentrator with a partially blocked intake can look perfectly normal while delivering noticeably less than its rated flow.

Choosing between types

If the patient is largely stationary and needs oxygen through the night, continuous flow is the only realistic choice. If they are active and out of the house for part of the day, a portable or pulse-dose unit for those hours with a continuous unit for sleep is a common and workable arrangement — and one that is often specified as a pair rather than a single device.

If you are specifying equipment for a clinic or a home-care programme, tell us the flow rates, the duty cycle and whether overnight use is involved, and we will map that to the right configuration.