Hyperbaric Chamber Safety: Contraindications and Precautions

OxySoothe Editorial

The single most common misunderstanding in hyperbaric safety is that the contraindications list is long and forbidding. It is not. The absolute list is genuinely short, the relative list is a matter of judgement rather than a prohibition, and the precautions that actually determine whether a session is well run are mostly about fire, ears and operator training.

This guide explains what screening is for, what the categories mean, and what to check before you or a client go into a chamber.

What screening is actually for

A screening questionnaire is not paperwork for its own sake. It exists to find a small number of situations where hyperbaric exposure should not proceed, and to identify the larger number where extra care or a modified protocol is needed.

  • It confirms that no absolute contraindication is present. This is the primary function and it is non-negotiable.
  • It identifies relative contraindications, where the decision is a clinical judgement about the individual rather than a rule.
  • It surfaces practical issues that will affect the session: ear and sinus conditions, recent surgery, medication, pregnancy.
  • It identifies conditions requiring a physician's opinion rather than an operator's judgement, which is what the escalation step is for.
  • It establishes a record for the clinical file, which matters if anything unexpected happens.

A questionnaire that is filled in once and never looked at again is decoration. A good one is reviewed by a clinician for anyone whose answers raise a question, and the outcome is written down.

Absolute contraindications

These are the conditions where hyperbaric exposure should not proceed, because the risk of serious harm outweighs any reason to run a session. The list is short and stable, and it is consistent across professional guidance.

  • An untreated pneumothorax. Pressure changes can cause air in the pleural space to expand, and an untreated pneumothorax is the most serious absolute contraindication in the field.
  • Recent treatment with certain chemotherapy agents that carry a recognised risk of lung injury under pressure, and specific drugs whose safety under pressure is not established.
  • Certain antibiotics used as topical or systemic agents inside the chamber, including the sulfonamide group, which are excluded by protocol.
  • Concurrent use of disulfiram or a similar agent, because of the interaction with the chamber environment.
  • Untreated or worsening respiratory infection where the person is systemically unwell.
  • Failure to be able to equalise the ears, which is dealt with below as a practical rather than an absolute matter.

A note on the last one and on pregnancy, which appears in the relative list rather than the absolute one. A well-run chamber with a trained operator can manage most pregnancy cases, but it requires a documented decision rather than a default.

Relative contraindications

These are not prohibitions. They are situations where the decision depends on the individual, on the protocol and on medical judgement, and where the correct answer is written down by someone qualified.

  • Pregnancy, at any stage, which requires an obstetric opinion and monitoring.
  • Ear and sinus conditions, including a recent cold, sinus infection, recent ear surgery, a perforated eardrum or middle-ear surgery. These are the most common reason a session is deferred in practice.
  • Chronic obstructive pulmonary disease or any condition where carbon dioxide retention is possible, which requires monitoring rather than assumption.
  • A history of seizures, and any condition where a seizure during a session would be dangerous.
  • Recent surgery, particularly where a wound or an anastomosis might be affected by the pressure change.
  • High fever, uncontrolled blood pressure, or a chest infection that is being actively treated.
  • Ocular conditions involving the lens, where pressure changes affect the eye.

It is worth saying plainly that being on the relative list does not mean a session cannot happen. It means somebody with the right qualification has to decide, and that the decision and its reasoning are recorded.

Ears, and why sessions get deferred

This deserves its own section because it is the practical issue that clients meet most often.

  • The middle ear is a gas-filled space and it has to equalise with the surrounding pressure as the chamber changes. Most people do this automatically by swallowing or yawning.
  • Teach the technique before the first session, not during it. A first-timer who cannot equalise and has to be taken out has had a bad experience that they will not repeat.
  • A blocked nose from a cold prevents equalisation, which is why a respiratory infection defers so many sessions.
  • The chamber operator should slow the pressure change for someone struggling, and should not treat the session as a test of toughness.
  • A technique that works going up usually works coming down, but the descent is where most people feel it and where the operator earns their keep.

Fire precautions

Combustion risk, not pressure, is the hazard that causes the most damage in this field, and every credible installation addresses it deliberately.

  • No ignition sources in the chamber: no phones, watches, fitness trackers, smoking materials, or heated devices of any kind.
  • No petroleum-based products on skin or clothing. Many creams, ointments, hair products and synthetic fabrics carry hydrocarbon residues that ignite far more easily in an oxygen-enriched environment.
  • Clothing guidance should be given in writing at the first session, not verbally, and staff should be able to explain why it matters.
  • Fire suppression appropriate to the chamber, with the correct extinguishing agent for an oxygen-enriched environment.
  • The operator should check the chamber interior before every session, every time, rather than assuming the previous occupant was careful.
  • Internal oxygen monitoring with an audible alarm, and a documented emergency evacuation and depressurisation procedure.

The clothing point is where most near-misses come from, and it is worth understanding rather than complying with. A product that is entirely safe in normal air can ignite readily when the surrounding oxygen concentration rises.

Pressure and gas density

  • Gas density rises with pressure, so the work of breathing increases and people tire faster at higher pressures than at sea level.
  • The pressure change rate matters as much as the final figure. A chamber that reaches its working pressure in three minutes is a different experience from one that takes twenty.
  • Above roughly two atmospheres, most protocols use pure oxygen delivery under pressure rather than relying on the surrounding air.
  • Longer sessions at higher pressure are more likely to produce fatigue, and the operator should shorten them accordingly.
  • CO2 accumulates in a closed chamber. Adequate ventilation or air exchange during a session is not a comfort measure, it is a safety one.

What a well-run operation looks like

  • A written screening questionnaire, reviewed by a clinician for anyone whose answers need it, with outcomes recorded.
  • A named medical supervisor with a documented role, and a clear escalation route.
  • Trained operators who can demonstrate the emergency procedure rather than describe it.
  • Pre-session checks of the chamber interior, the oxygen supply, the fire system, the alarm and the communication.
  • A documented emergency procedure, and a regular rehearsal of it.
  • Records of every session: pressure, duration, delivery method, any events and the operator on duty.
  • Service and calibration on schedule, with certificates kept and available for inspection.

Questions to ask a clinic

  • What is the screening process, and who reviews the questionnaire results?
  • Who is medically responsible for the programme, and what is their qualification?
  • What is the emergency procedure, and how often is it rehearsed?
  • What fire suppression and internal oxygen monitoring are installed, and what is checked before each session?
  • Are cotton clothing and personal items checked, and what is the written clothing policy?
  • What is the recorded service and calibration schedule, and can I see the certificates?
  • What happens if a client has an ear problem on the day?

So to answer the question in the title: the absolute contraindication list is short and specific, the relative list is a matter of documented clinical judgement, and the precautions that decide whether a session is safe are fire, ears, ventilation and operator competence. A clinic that screens properly will sometimes tell you not to proceed, and that is a sign of a well-run operation rather than a reason to look elsewhere.

If you are setting up a programme and want a written screening and operating procedure drafted around your chamber and your jurisdiction, send us the model and the protocol and we will work it out.

Tell us your needs

We can tailor a solution for you